Application
Connecting cable between frequency convertor and motor. This motor power supply cable is used for the frequency converters and assures electromagnetic compatibility in plants and buildings Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps,Ventilators, conveyor belts and air-conditioning installations and similar applications.
Technical Data
Standard: Adapted DINVDE 0207/0250/0295
NominalVoltage: UO / U 600 / 1000V
Insulation Resistance: Min. 200 GΩ x cm
Temperature Range: Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius: Flexing 15 x cable ø. Fixed installation 4 x cable ø
TestVoltage: 4000V
Cable Construction
Bare copper, fine wire conductors, according to EN 60228 cl. 5.
PE ( polyethylene ) core insulation.
Core colours: black, brown, grey, green-yellow.
Cores stranded in concentric layers.
1. screening with special aluminum foil.
2. screening with copper braiding, tinned copper.
Transparent special PVC outer sheath.
Properties
Flame retardant according to EN 60332-1-2.
Low mutual capacitance.
Features PE-insulation secures a lower dielectric loss, double potential strength, high longevity and low screen-interference currents.
Installation in hazardous areas.
Meets EMC requirements.
Due to the optimal screening an interference-free operation of frequency converters is obtained